Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/1861
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTomaselli, Lucas de Oliveirapt_BR
dc.contributor.authorVitti, Rafael Pinopt_BR
dc.contributor.authorBertolo, Marcus Vinicius Loureiropt_BR
dc.contributor.authorAbuna, Gabrielpt_BR
dc.contributor.authorBrandt, William Cunhapt_BR
dc.contributor.authorSinhoreti, Mário Alexandre Coelhopt_BR
dc.date.accessioned2019-09-12T16:26:06Z-
dc.date.available2019-09-12T16:26:06Z-
dc.date.issued2016-
dc.citation.volume15pt_BR
dc.citation.issue4pt_BR
dc.citation.spage252-
dc.citation.epage257-
dc.identifier.doi10.20396/bjos.v15i4.8650031pt_BR
dc.identifier.issn16773217-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85030175455&doi=10.20396%2fbjos.v15i4.8650031&partnerID=40&md5=86d49bb075e0607c2f201a3678ad9e8a-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/1861-
dc.description.abstractPurposes: This study aimed to assess the dimensional accuracy of five commercial alginates verified in stone casts. Methods: Each alginate impression (Cavex ColorChange, Cavex Holland BV; Jeltrate Plus, Dentsply; Hydrogum, Zhermack; Kromopan 100, Lascod; Ezact Kromm, Vigodent) was performed on partially edentulous standard stainless steel mandibular arch cast with reference points on teeth 33, 43, 37 and 47. On the stainless steel cast, the anteroposterior (33-37 and 43-47) and transverse (33-43 and 37-47) distances were measured in a stereomicroscope at 30x magnification and 0.5 μm accuracy. The distances between these points were measured three times, obtaining an average, which was analyzed statistically and compared with the distances obtained from the stone casts. For each alginate the casts were poured gypsum (n = 5) immediately and after a period of 1, 2, 3 and 5 days of the impression procedure. Results: The dimensional accuracy values of stone and stainless steel casts were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). The results showed significant differences between the alginates; however, no differences in dimensional accuracy were found among the different storage times of alginate impression. Conclusions: It can be concluded that the alginate impressions can be stored for up to 5 days.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:26:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2016en
dc.languageInglêspt_BR
dc.publisherPiracicaba Dental School - UNICAMP-
dc.relation.ispartofBrazilian Journal of Oral Sciences-
dc.rightsAcesso Abertopt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceScopuspt_BR
dc.subject.otherDental impression materialen
dc.subject.otherDimensional measurement accuracyen
dc.subject.otherMandibular prosthesisen
dc.titleAccuracy of partially edentulous arch impressions obtained from different alginates and storage timesen
dc.typeArtigo de Periódicopt_BR
dc.description.affiliationTomaselli, L.O., University of Campinas, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil-
dc.description.affiliationVitti, R.P., University of Taubaté, School of Dentistry, Department of Prosthodontics, Taubaté, SP, Brazil-
dc.description.affiliationBertolo, M.V.L., University of Campinas, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil-
dc.description.affiliationAbuna, G., University of Campinas, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil-
dc.description.affiliationBrandt, W.C., University of Santo Amaro, School of Dentistry, Department of Implantology, São Paulo, SP, Brazil-
dc.description.affiliationSinhoreti, M.A.C., University of Campinas, Piracicaba Dental School, Department of Restorative Dentistry, Piracicaba, SP, Brazil-
dc.identifier.scopus2-s2.0-85030175455-
dc.contributor.scopus37091702000pt_BR
dc.contributor.scopus54918500200pt_BR
dc.contributor.scopus56600198600pt_BR
dc.contributor.scopus55990644200pt_BR
dc.contributor.scopus14424008300pt_BR
dc.contributor.scopus6603249112pt_BR
Appears in Collections:Artigos de Periódicos

Files in This Item:
File SizeFormat 
2-s2.0-85030175455.pdf335.14 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons