Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/1968
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTakatsui, Fabianapt_BR
dc.contributor.authorAndrade, Marcelo Ferrarezi dept_BR
dc.contributor.authorNeisser, Maximiliano Pieropt_BR
dc.contributor.authorBarros, Luiz Antônio Borellipt_BR
dc.contributor.authorLoffredo, Leonor de Castro Monteiropt_BR
dc.date.accessioned2019-09-12T16:32:39Z-
dc.date.available2019-09-12T16:32:39Z-
dc.date.issued2012-
dc.citation.volume26pt_BR
dc.citation.issue6pt_BR
dc.citation.spage578-
dc.citation.epage583-
dc.identifier.doi10.1590/S1806-83242012005000025-
dc.identifier.issn1807-3107-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/1968-
dc.description.abstractThe aim of this study was to analyze the color alterations performed by the CIE L*a*b* system in the digital imaging of shade guide tabs, which were obtained photographically according to the automatic and manual modes. This study also sought to examine the observers' agreement in quantifying the coordinates. Four Vita Lumin Vaccum shade guide tabs were used: A3.5, B1, B3 and C4. An EOS Canon digital camera was used to record the digital images of the shade tabs, and the images were processed using Adobe Photoshop software. A total of 80 observations (five replicates of each shade according to two observers in two modes, specifically, automatic and manual) were obtained, leading to color values of L*, a* and b*. The color difference (ΔE) between the modes was calculated and classified as either clinically acceptable or unacceptable. The results indicated that there was agreement between the two observers in obtaining the L*, a* and b* values related to all guides. However, the B1, B3, and C4 shade tabs had ΔE values classified as clinically acceptable (ΔE = 0.44, ΔE = 2.04 and ΔE = 2.69, respectively). The A3.5 shade tab had a ΔE value classified as clinically unacceptable (ΔE = 4.17), as it presented higher values for luminosity in the automatic mode (L* = 54.0) than in the manual mode (L* = 50.6). It was concluded that the B1, B3 and C4 shade tabs can be used at any of the modes in digital camera (manual or automatic), which was a different finding from that observed for the A3.5 shade tab.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:32:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2012en
dc.languageInglêspt_BR
dc.publisherSociedade Brasileira de Pesquisa Odontológica - SBPqO-
dc.publisher.countryBrasilpt_BR
dc.relation.ispartofBrazilian Oral Research-
dc.rightsAcesso Abertopt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0*
dc.sourceScielopt_BR
dc.subject.otherToothen
dc.subject.otherColor Perceptionen
dc.subject.otherImage Processing, Computer-Assisteden
dc.titleCIE L*a*b*: comparison of digital images obtained photographically by manual and automatic modesen
dc.typeArtigo de Periódicopt_BR
dc.description.affiliation[Neisser, Maximiliano Piero] Universidade de Taubaté, Brazil-
dc.description.affiliationBarros, Luiz Antônio Borelli; Loffredo, Leonor de Castro Monteiro] Universidade Estadual Paulista, Brazil-
dc.description.affiliationTakatsui, Fabiana; Andrade, Marcelo Ferrarezi de] Universidade Estadual Paulista, Brazil-
dc.subject.researchareaDentistry, Oral Surgery & Medicineen
dc.subject.scieloareaDentistry, Oral Surgery & Medicineen
dc.identifier.scieloSCIELO:S1806-83242012000600015-
Appears in Collections:Artigos de Periódicos

Files in This Item:
File SizeFormat 


This item is licensed under a Creative Commons License Creative Commons