Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/2081
metadata.dc.type: Artigo de Periódico
Title: Influence of plasma-based dry etching on the bond strength of Y-TZP ceramic
Authors: Alvim H.C.N.
Silva-Concílio, Laís Regiane da
De Queiroz J.R.C.
Amaral M.
Vitti, Rafael Pino
Neves, Ana Christina Claro
Abstract: The aim of this study was to evaluate the bond strength between an yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic and a luting agent when submitted to plasma etching surface treatment before and after thermocycling (TC) with 3000 cycles of 5°C-55°C. The null hypothesis was that the surface treatments and thermocycling would not influence the bond strength. A total of 160 Y-TZP ceramic blocks in 2 sizes (10 size 1 and 10 size 2 blocks in each group) were distributed into 8 groups: group C (control), no surface treatment; group C-TC, TC without prior surface treatment; group SAO, sandblasting with aluminum oxide (Al2O3); group SAOTC, sandblasting with Al2O3 followed by TC; group SAOS, sandblasting with silica-coated Al2O3; group SAOS-TC, sandblasting with silica-coated Al2O3 followed by TC; group PE, plasma etching; and group PE-TC, plasma etching followed by TC. In each group, size 1 blocks were cemented to size 2 blocks to fabricate specimens for microshear bond strength testing (n = 10 per group). Cementation followed surface treatments (except in control groups) and preceded any TC. All specimens were cemented using a luting agent that contained 10-methacryloyloxydecyl dihydrogen phosphate (MDP). The specimens were submitted to a microshear bond strength test and the means were analyzed with a 2-factor analysis of variance and Tukey test. Group PE showed the highest bond strength value before thermocycling (17.31 MPa). After thermocycling, the highest value was observed in the SAO-TC group (9.73 MPa), and statistically significant differences were observed between SAOS-TC and SAOTC (P < 0.05) and PE-TC and SAO-TC (P < 0.05). Plasma etching improved the bond strength values between the Y-TZP ceramic and MDP-containing luting agent before thermocycling. After thermocycling, all groups showed lower bond strength values. © 2018 by the Academy of General Dentistry.
metadata.dc.language: Inglês
Publisher: Academy of General Dentistry
metadata.dc.rights: Acesso Restrito
URI: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85048817722&partnerID=40&md5=a22b5dfa6d27d0db45d69cc61500855d
http://repositorio.unitau.br/jspui/handle/20.500.11874/2081
Issue Date: 2018
Appears in Collections:Artigos de Periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.