Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/2297
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChianello G.pt_BR
dc.contributor.authorLeal Specian V.pt_BR
dc.contributor.authorHardt L.C.F.pt_BR
dc.contributor.authorRaldi D.P.pt_BR
dc.contributor.authorLage-Marques, José Luiz da Silvapt_BR
dc.contributor.authorHabitante, Sandra Márciapt_BR
dc.date.accessioned2019-09-12T16:33:09Z-
dc.date.available2019-09-12T16:33:09Z-
dc.date.issued2008-
dc.citation.volume19pt_BR
dc.citation.issue2pt_BR
dc.citation.spage109-
dc.citation.epage113-
dc.identifier.issn1036440-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-61449505249&partnerID=40&md5=b9d0fd2fa6d2a7ac924a43e570185f3f-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/2297-
dc.description.abstractDuring endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary files from different commercial brands (ProFile, Protaper, Race, Hero and K3 Endo) were removed directly from their packages and had their final 3 mm examined with a scanning electron microscope at ×190 magnification with no previous preparation. The images were evaluated by 3 skillful, calibrated, blinded observers according to the following criteria: cutting edge, debris, grooves, microcavities, tip shape, tip position, scraping and transition angle. Data were recorded in worksheets designed for the study. Irregular edges were observed in 50-100% of the files. Except for ProFile, all commercial brands presented surface debris in 100% of samples. Only Race files showed no grooves or microcavities. K3 Endo files presented the best tip centralization. Excetp for ProTaper files, all commercial brands presented blunt-cutting edges in 100% of samples. All types of files presented surface scraping. K3 Endo files and Protaper had a high percentage of transition angle. Based on the evaluation criteria used in the present study, most samples presented a minimum of 2 alterations and a maximum of 7 alterations per instrument. Under the tested conditions, the quality of the surface finishing of the examined instruments was not as expected, given that no instrument was free of imperfections and most of them presented atleast 2 and up to 7 types of surface defects. These results suggest that the manufacturing process and the packaging conditions of rotary endodontic instruments are far from ideal.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:33:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2008en
dc.languageInglêspt_BR
dc.relation.ispartofBrazilian Dental Journal-
dc.rightsAcesso Restritopt_BR
dc.sourceScopuspt_BR
dc.subject.otherEndodontic instrumentsen
dc.subject.otherManufacturing defectsen
dc.subject.otherScanning electron microscopyen
dc.subject.otherSurface finishingen
dc.subject.otherarticleen
dc.subject.otherdental technologyen
dc.subject.otherendodonticsen
dc.subject.otherequipment designen
dc.subject.otherhumanen
dc.subject.otherinstrumentationen
dc.subject.othermaterials testingen
dc.subject.otherrotationen
dc.subject.otherscanning electron microscopyen
dc.subject.otherstandarden
dc.subject.othersurface propertyen
dc.subject.otherEquipment Designen
dc.subject.otherHumansen
dc.subject.otherMaterials Testingen
dc.subject.otherMicroscopy, Electron, Scanningen
dc.subject.otherRoot Canal Preparationen
dc.subject.otherRotationen
dc.subject.otherSurface Propertiesen
dc.subject.otherTechnology, Dentalen
dc.titleSurface finishing of unused rotary endodontic instruments: A SEM studyen
dc.typeArtigo de Periódicopt_BR
dc.description.affiliationChianello, G., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.description.affiliationLeal Specian, V., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.description.affiliationHardt, L.C.F., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.description.affiliationRaldi, D.P., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.description.affiliationLage-Marques, J.L., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.description.affiliationHabitante, S.M., Dental School, University of Taubaté, Taubaté, SP, Brazil-
dc.identifier.scopus2-s2.0-61449505249-
dc.contributor.scopus26121090000pt_BR
dc.contributor.scopus36343587600pt_BR
dc.contributor.scopus26121183900pt_BR
dc.contributor.scopus26121368600pt_BR
dc.contributor.scopus6602291884pt_BR
dc.contributor.scopus6506689008pt_BR
Appears in Collections:Artigos de Periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.