Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/2420
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSilva-Concílio, Laís Regiane dapt_BR
dc.contributor.authorMeloto C.B.pt_BR
dc.contributor.authorNeves A.C.pt_BR
dc.contributor.authorCunha L.G.pt_BR
dc.contributor.authorRizzatti-Barbosa C.M.pt_BR
dc.date.accessioned2019-09-12T16:37:13Z-
dc.date.available2019-09-12T16:37:13Z-
dc.date.issued2012-
dc.citation.volume25pt_BR
dc.citation.issue3pt_BR
dc.citation.spage312-
dc.citation.epage317-
dc.identifier.issn3264815-
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84880822055&partnerID=40&md5=a2cb7c028c6f998632f67be0674e2f28-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/2420-
dc.description.abstractThe flasking and polymerization technique for resins can introduce stresses during processing which may lead to denture base distortions, artificial teeth displacement and increases in the occlusal vertical dimension (OVD). This study investigated whether the association of microwave heat-activation (MH) and bimaxillary flasking (BF) minimizes the possible increases in OVD after prostheses processing. Forty pairs of complete dentures were waxed with the artificial teeth in closed occlusion and divided into four groups according to investing and heating methods: G1 (control) = monomaxillary/water bath; G2 = monomaxillary/microwave; G3 = bimaxillary/water bath and G4 = bimaxillary/microwave. OVD was measured using a digital caliper before and after prostheses processing. Results were submitted to statistical analysis (Student's t-test for multiple comparisons and post hoc ANOVA, alpha = 0.05). Comparison of values before and after processing showed that OVD increased in all groups after polymerization (p < 0.001), regardless of flasking and polymerization methods. Statistically, G2 had the greatest difference in OVD when compared to G1 (p = 0.014), G3 (p = 0.019) and G4 (p = 0.024). G3 and G4 showed similar results statistically when compared to G1 (control). Both investing and heating methods resulted in an increase in OVD after processing. However, the prostheses invested in bimaxillary flasks showed the lowest changes in OVD, regardless of the polymerization method.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:37:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2012en
dc.languageInglêspt_BR
dc.relation.ispartofActa odontológica latinoamericana : AOL-
dc.rightsAcesso Restritopt_BR
dc.sourceScopuspt_BR
dc.subject.otherarticleen
dc.subject.othercomplete dentureen
dc.subject.otherpolymerizationen
dc.subject.othertooth occlusionen
dc.subject.otherDenture, Completeen
dc.subject.otherPolymerizationen
dc.subject.otherVertical Dimensionen
dc.titleInfluence of different flasking and polymerizing methods on the occlusal vertical dimension of complete dentures.en
dc.typeArtigo de Periódicopt_BR
dc.description.affiliationSilva-Concílio, L.R., Department of Prosthodontics, Dental School, University of Taubaté, TaubatéSão Paulo, Brazil-
dc.description.affiliationMeloto, C.B.-
dc.description.affiliationNeves, A.C.-
dc.description.affiliationCunha, L.G.-
dc.description.affiliationRizzatti-Barbosa, C.M.-
dc.identifier.scopus2-s2.0-84880822055-
dc.contributor.scopus8502637600pt_BR
dc.contributor.scopus21933997200pt_BR
dc.contributor.scopus25929472300pt_BR
dc.contributor.scopus54790562800pt_BR
dc.contributor.scopus6603354760pt_BR
Appears in Collections:Artigos de Periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.