Please use this identifier to cite or link to this item:
http://repositorio.unitau.br/jspui/handle/20.500.11874/2680
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Barcellos, Aline Serrado de Pinho | pt_BR |
dc.contributor.author | Marinho, Caroline Cotes | pt_BR |
dc.contributor.author | Miranda, Jean Soares | pt_BR |
dc.contributor.author | Amaral, Marina | pt_BR |
dc.contributor.author | Shiino, Marcos Yutaka | pt_BR |
dc.contributor.author | Kimpara, Estevao Tomomitsu | pt_BR |
dc.date.accessioned | 2019-09-12T16:53:37Z | - |
dc.date.available | 2019-09-12T16:53:37Z | - |
dc.date.issued | 2018 | - |
dc.citation.volume | 81 | pt_BR |
dc.citation.spage | 173 | - |
dc.citation.epage | 177 | - |
dc.identifier.doi | 10.1016/j.jmbbm.2018.02.007 | pt_BR |
dc.identifier.issn | 1751-6161 | - |
dc.identifier.issn | 1878-0180 | - |
dc.identifier.uri | http://repositorio.unitau.br/jspui/handle/20.500.11874/2680 | - |
dc.description.abstract | The aim of this study was compare the effect of two in vitro ageing protocols to intraoral aging on the flexural strength of a lithium disilicate (LD) ceramic bars with clamped ends. After polishing and crystallization, the both ends of the bars were cemented to a metallic device and subjected to mechanical cycling, thermomechanical cycling, or intraoral ageing. Ten volunteers used an intraoral device - similar to an occlusal splint with a balanced contact condition on the occlusal surface of the ceramic bar - during 8 h night time / 30 days. Both in vitro and intraoral ageing decreased the flexural residual strength of LD, with the lowest values obtained after intraoral ageing. Thus, the in vitro ageing protocols tested in this study revealed to be less deleterious than intraoral ageing of LD. | en |
dc.description.provenance | Made available in DSpace on 2019-09-12T16:53:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2018 | en |
dc.language | Inglês | pt_BR |
dc.publisher | Elsevier Science Bv | - |
dc.publisher.country | Holanda | pt_BR |
dc.relation.ispartof | Journal of the Mechanical Behavior of Biomedical Materials | - |
dc.rights | Em verificação | pt_BR |
dc.source | Web of Science | pt_BR |
dc.subject.other | Fixed Partial Dentures | en |
dc.subject.other | Glass-Ceramics | en |
dc.subject.other | Clinical-Performance | en |
dc.subject.other | Fracture Strength | en |
dc.subject.other | Dental Ceramics | en |
dc.subject.other | Gold Alloy | en |
dc.subject.other | Titanium | en |
dc.subject.other | Crowns | en |
dc.subject.other | Hot | en |
dc.title | Effect of fatigue protocols on flexural strength of lithium disilicate bars with clamped-ends | en |
dc.type | Artigo de Periódico | pt_BR |
dc.identifier.wos | WOS:000430772200019 | - |
dc.description.affiliation | [de Pinho Barcellos, Aline Serrado; Marinho, Caroline Cotes; Miranda, Jean Soares; Shiino, Marcos Yutaka] Univ Estadual Paulista, Inst Sci & Technol, Sao Paulo, Brazil | - |
dc.description.affiliation | [Amaral, Marina; Kimpara, Estevao Tomomitsu] Universidade de Taubaté (Unitau), Dept Dent, Sao Paulo, Brazil | - |
dc.subject.wosarea | Engineering, Biomedical | en |
dc.subject.wosarea | Materials Science, Biomaterials | en |
dc.subject.researcharea | Engineering | en |
dc.subject.researcharea | Materials Science | en |
Appears in Collections: | Artigos de Periódicos |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.