Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/3060
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGoncalves, Fernanda de Cassia Papaizpt_BR
dc.contributor.authorAmaral, Marinapt_BR
dc.contributor.authorBorges, Alexandre Luiz Soutopt_BR
dc.contributor.authorGoncalves, Luiz Fernando Martinspt_BR
dc.contributor.authorPaes-Junior, Tarcisio Jose de Arrudapt_BR
dc.date.accessioned2019-09-12T16:57:06Z-
dc.date.available2019-09-12T16:57:06Z-
dc.date.issued2018-
dc.citation.volume119pt_BR
dc.citation.issue4pt_BR
dc.citation.spage606-
dc.citation.epage610-
dc.identifier.issn0022-3913-
dc.identifier.issn1097-6841-
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/3060-
dc.description.abstractStatement of problem. Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. Purpose. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Material and methods. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (alpha=.05). Results. The mean maximum load standard deviation for the molar group was 393.4 +/- 95.0 N with reinforcement and 305.4 +/- 76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 +/- 283.7 N with reinforcement and 605.3 +/- 90.5 N without reinforcement (P=.001). Conclusions. Reinforcement with nylon mesh increased the mean maximum load of implant supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture.en
dc.description.provenanceMade available in DSpace on 2019-09-12T16:57:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2018en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)pt_BR
dc.languageInglêspt_BR
dc.publisherMosby-Elsevier-
dc.publisher.countryEstados Unidospt_BR
dc.relation.ispartofJournal of Prosthetic Dentistry-
dc.rightsEm verificaçãopt_BR
dc.sourceWeb of Sciencept_BR
dc.subject.otherFixed Dental Prosthesesen
dc.subject.otherStress-Distributionen
dc.subject.otherBoneen
dc.subject.otherFrameworken
dc.subject.otherFiten
dc.titleFracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro studyen
dc.typeArtigo de Periódicopt_BR
dc.contributor.orcidBorges, Alexandre https://orcid.org/0000-0002-5707-7565pt_BR
dc.contributor.orcidBorges, Alexandre LS https://orcid.org/0000-0002-5707-7565pt_BR
dc.contributor.orcidAmaral, Marina https://orcid.org/0000-0002-4301-2760pt_BR
dc.contributor.orcid, Tarcisio https://orcid.org/0000-0001-8446-0474pt_BR
dc.contributor.researcheridBorges, Alexandre/J-6449-2019pt_BR
dc.contributor.researcheridBorges, Alexandre LS/A-9477-2014pt_BR
dc.identifier.wosWOS:000431090700022-
dc.description.affiliation[Papaiz Goncalves, Fernanda de Cassia] Inst Aeronaut Technol ITA, Postdoctoral Program, Sao Jose Dos Campos, Brazil-
dc.description.affiliation[Amaral, Marina] Universidade de Taubaté (Unitau) , Dept Dent, Dent Prostheses-
dc.description.affiliation[Souto Borges, Alexandre Luiz; de Arruda Paes-Junior, Tarcisio Jose] Sao Paulo State Univ, UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Ave Engenheiro Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, Brazil-
dc.description.affiliation[Martins Goncalves, Luiz Fernando] Inst Aeronaut Technol ITA, Applicat Lab, Engn, Sao Jose Dos Campos, Brazil-
dc.subject.wosareaDentistry, Oral Surgery & Medicineen
dc.subject.researchareaDentistry, Oral Surgery & Medicineen
Appears in Collections:Artigos de Periódicos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.