Please use this identifier to cite or link to this item:
http://repositorio.unitau.br/jspui/handle/20.500.11874/3060
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Goncalves, Fernanda de Cassia Papaiz | pt_BR |
dc.contributor.author | Amaral, Marina | pt_BR |
dc.contributor.author | Borges, Alexandre Luiz Souto | pt_BR |
dc.contributor.author | Goncalves, Luiz Fernando Martins | pt_BR |
dc.contributor.author | Paes-Junior, Tarcisio Jose de Arruda | pt_BR |
dc.date.accessioned | 2019-09-12T16:57:06Z | - |
dc.date.available | 2019-09-12T16:57:06Z | - |
dc.date.issued | 2018 | - |
dc.citation.volume | 119 | pt_BR |
dc.citation.issue | 4 | pt_BR |
dc.citation.spage | 606 | - |
dc.citation.epage | 610 | - |
dc.identifier.issn | 0022-3913 | - |
dc.identifier.issn | 1097-6841 | - |
dc.identifier.uri | http://repositorio.unitau.br/jspui/handle/20.500.11874/3060 | - |
dc.description.abstract | Statement of problem. Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. Purpose. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Material and methods. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (alpha=.05). Results. The mean maximum load standard deviation for the molar group was 393.4 +/- 95.0 N with reinforcement and 305.4 +/- 76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 +/- 283.7 N with reinforcement and 605.3 +/- 90.5 N without reinforcement (P=.001). Conclusions. Reinforcement with nylon mesh increased the mean maximum load of implant supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. | en |
dc.description.provenance | Made available in DSpace on 2019-09-12T16:57:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2018 | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | pt_BR |
dc.language | Inglês | pt_BR |
dc.publisher | Mosby-Elsevier | - |
dc.publisher.country | Estados Unidos | pt_BR |
dc.relation.ispartof | Journal of Prosthetic Dentistry | - |
dc.rights | Em verificação | pt_BR |
dc.source | Web of Science | pt_BR |
dc.subject.other | Fixed Dental Prostheses | en |
dc.subject.other | Stress-Distribution | en |
dc.subject.other | Bone | en |
dc.subject.other | Framework | en |
dc.subject.other | Fit | en |
dc.title | Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study | en |
dc.type | Artigo de Periódico | pt_BR |
dc.contributor.orcid | Borges, Alexandre https://orcid.org/0000-0002-5707-7565 | pt_BR |
dc.contributor.orcid | Borges, Alexandre LS https://orcid.org/0000-0002-5707-7565 | pt_BR |
dc.contributor.orcid | Amaral, Marina https://orcid.org/0000-0002-4301-2760 | pt_BR |
dc.contributor.orcid | , Tarcisio https://orcid.org/0000-0001-8446-0474 | pt_BR |
dc.contributor.researcherid | Borges, Alexandre/J-6449-2019 | pt_BR |
dc.contributor.researcherid | Borges, Alexandre LS/A-9477-2014 | pt_BR |
dc.identifier.wos | WOS:000431090700022 | - |
dc.description.affiliation | [Papaiz Goncalves, Fernanda de Cassia] Inst Aeronaut Technol ITA, Postdoctoral Program, Sao Jose Dos Campos, Brazil | - |
dc.description.affiliation | [Amaral, Marina] Universidade de Taubaté (Unitau) , Dept Dent, Dent Prostheses | - |
dc.description.affiliation | [Souto Borges, Alexandre Luiz; de Arruda Paes-Junior, Tarcisio Jose] Sao Paulo State Univ, UNESP, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Ave Engenheiro Francisco Jose Longo 777, BR-12245000 Sao Jose Dos Campos, Brazil | - |
dc.description.affiliation | [Martins Goncalves, Luiz Fernando] Inst Aeronaut Technol ITA, Applicat Lab, Engn, Sao Jose Dos Campos, Brazil | - |
dc.subject.wosarea | Dentistry, Oral Surgery & Medicine | en |
dc.subject.researcharea | Dentistry, Oral Surgery & Medicine | en |
Appears in Collections: | Artigos de Periódicos |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.