Please use this identifier to cite or link to this item: http://repositorio.unitau.br/jspui/handle/20.500.11874/484
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorNohara, Evandro Luíspt_BR
dc.contributor.authorSimões, Heleno Ribeiropt_BR
dc.date.accessioned2019-06-19T18:30:10Z-
dc.date.available2019-06-19T18:30:10Z-
dc.date.issued2012pt_BR
dc.identifier.urihttp://repositorio.unitau.br/jspui/handle/20.500.11874/484-
dc.descriptionOrientação: Prof. Dr. Evandro Luís Noharapt_BR
dc.descriptionDissertação (Mestrado) - Universidade de Taubaté, Departamento de Engenharia Mecânica e Elétrica, Taubaté, 2012pt_BR
dc.description.abstractResumo: Nas construções de caldeiras de força, vasos de pressão e outros tipos de equipamentos para os diversos segmentos industriais tem exigido da engenharia de materiais um desenvolvimento tecnológico para melhores processos na obtenção de materiais fundidos, forjados, laminados e outros. Desenvolver recursos tecnológicos que minimizem a presença de imperfeições que possam comprometer a integridade estrutural dos equipamentos que operam com pressão tem sido uma busca constante tanto nas usinas como nas indústrias de bens de capital nas fases das construções. Uma construção implica em seleção de materiais, projeto, fabricação, exames, inspeção, testes, certificação e dispositivos de alívio que atendam aos requisitos dos códigos e normas. Estes requisitos estão cada vez maiores e estabelecem limites para a existência destas imperfeições vão de encontro à necessidade de lançar mão de métodos de ensaios não destrutivos que permitam sempre a melhor probabilidade de detecção. Os processos de controle da qualidade tem buscado por meio das novas tecnologias aumentarem a sua sensibilidade, visando à detecção de descontinuidades que hoje são detectadas pelos métodos convencionais. Em termos de ensaios não destrutivos, as exigências para o ensaio radiográfico convencional estão no limite da sensibilidade dos filmes radiográficos industriais disponíveis, além do compromisso de buscar um tempo de exposição menor ser sempre um fator importante a ser considerado na qualidade, segurança e produtividade tanto na fábrica como no campo. O objetivo deste trabalho foi estudar e avaliar a técnica de radiografia computadorizada (RC) em relação à radiografia convencional para inspeção dos materiais, utilizando os parâmetros de avaliação, tais como, relação sinal ruído, resolução espacial, ferramentas para detectabilidade, sensibilidade ao contraste e tons de cinza, que são aplicáveis nas avaliações de imagens digitais. Para a avaliação da técnica de radiografia industrial digital foi utilizado um corpo-de-prova fabricada pelo processo de fundição com espessura de 75 a 150mm, com defeitos típicos do processo. O corpo-de-prova foi radiografado com a técnica convencional e digital. Na técnica convencional foram utilizados os filmes radiográficos industriais, tipos I e II do ASTM E 1815, um acelarador linear Varian modelo Linatron 400 de 4 MeV e duas fontes de Cobalto-60 com atividades diferentes. Na técnica computadorizada foram utilizados as mesmas fontes de radiação, uma placa de fósforo denominada IXP e um equipamento CR-50P ambos da GE IT. Pelos resultados obtidos pode-se verificar que a radiografia digital com os equipamentos avaliados, atende satisfatoriamente os códigos e normas que são utilizadas na avaliação de peças fundidas. A técnica mostrou-se mais qualitativa quando na avaliação das descontinuidades localizadas nas seções críticas, pois o sistema RC possibilita a utilização de ferramenta de perfil de linha que fornece os valores de nível de cinza ao longo de uma trajetória linear demarcada na área da imagem da descontinuidade. Com isto, mesmo em poucos experimentos e um único sistema de RC pode-se concluir que a técnica é bastante vantajosa na detecção de descontinuidades nos processos de fabricação e que atendeu tanto os requisitos do ASTM E 272 para o cobre ou o ASME Seção VIII Divisão 1, Apêndice 7 que referenciam os padrões radiográficos conforme as normas ASTM E-186 e ASTM E-280 para aços fundidos.pt_BR
dc.description.abstractAbstract: In the constructions of power boilers, pressure vessels and other equipment for several industries has required the development of materials engineering technology for better processes in obtaining materials cast, forged, rolled, and others. Develop technological resources that minimize the presence of imperfections that could compromise the structural integrity of the equipment operating pressure has been a constant search both in plants and in capital goods industries phases of construction. A construction involves materials selection, design, fabrication, testing, inspection, testing, certification, and relief devices that meet the requirements of codes and standards. These requirements are increasing and establish limits for the existence of these imperfections go against the need to resort to non-destructive testing methods that enable always the best probability of detection. The processes of quality control have sought through new technologies increase their sensitivity in order to detect discontinuities of today are detected by conventional methods. In terms of non-destructive testing, requirements for conventional radiographic testing are at the limit of sensitivity of available industrial radiographic films, besides the commitment to seek a lower exposure time is always an important factor to be considered in quality, safety and productivity both in the factory and in the field. The aim of this work was to study and evaluate the technical radiography Computed (RC) compared to conventional radiography for inspection of materials, using evaluation parameters such as signal to noise ratio, spatial resolution, and tools for detectability, contrast sensitivity and grayscale, which apply in evaluations of digital images. For the evaluation of industrial radiography technique it was used a test specimen manufactured by the casting process with thickness from 75 to 150 mm, with typical defects in the process. The test specimen was X-rayed with the conventional and digital techniques. In the conventional technique were used industrial radiographic films types I and II to ASTM E -1815, a linear accelerator Varian model 400 Linatron 4 MeV and two cobalt-60 sources with different activities. In the technique computed were used the same radiation source, a phosphor plate IPX and an apparatus called CR-50P both GE IT. From the results it can be seen that with digital radiography equipment evaluated satisfactorily meets the codes and standards that are used in the evaluation of castings. The technique was more qualitative evaluation when the discontinuities located in critical sections for the system to use RC allows tool profile line shows values of gray level along a linear path demarcated in the image area discontinuity. With this, even in a few experiments a single system and RC can be concluded that the technique is quite advantageous in the detection of discontinuities in the manufacturing processes and that both met the requirements of ASTM E 272 for copper or ASME Section VIII Division 1, Appendix 7 that reference radiographic patterns according to ASTM E-186 and ASTM E-280 for steel castings.pt_BR
dc.description.provenanceMade available in DSpace on 2019-06-19T18:30:10Z (GMT). No. of bitstreams: 1 Heleno Ribeiro Simoes.pdf: 3595608 bytes, checksum: 8f8ef4589e8649ab2a37669277a564de (MD5) Previous issue date: 2012en
dc.format.extent160 f. : il. ; 30 cm.pt_BR
dc.format.mimetypeapplication/pdfpt_BR
dc.languagePortuguêspt_BR
dc.publisherUniversidade de Taubatépt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentDepartamento de Engenharia Mecânica e Elétricapt_BR
dc.publisher.programPrograma de Pós-graduação em Engenharia Mecânicapt_BR
dc.publisher.initialsUNITAUpt_BR
dc.relation.requiresRequisitos do sistema: Software para leitura de arquivo em PDF.pt_BR
dc.rightsAcesso Abertopt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0*
dc.subjectRadiografia computadorizadapt_BR
dc.subjectPeças fundidaspt_BR
dc.subjectPlacas de fósforopt_BR
dc.subjectAceleradores linearespt_BR
dc.subjectFonte de cobalto-60pt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA MECANICApt_BR
dc.titleAvaliação de materiais usando a radiografia computadorizada (CR) empregando um acelerador linear e cobalto - 60 como fontes de altas energiaspt_BR
dc.title.alternativeEvaluation of materials using computed radiography (CR) employing a linear accelerator and cobalt - 60 as sources of high energypt_BR
dc.typeDissertaçãopt_BR
dc.contributor.otherSilva, Aluisio Pinto dapt_BR
dc.contributor.otherMoreira, Edson Vasquespt_BR
dc.contributor.otherUniversidade de Taubaté. Programa de Pós-graduação em Engenharia Mecânicapt_BR
dc.description.degreelevelMestrado em Engenharia Mecânicapt_BR
Appears in Collections:Dissertações - Engenharia Mecânica - PPGEM/MEM

Files in This Item:
File SizeFormat 
Heleno Ribeiro Simoes.pdf3.51 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons